More info
Our instagram
alt
alt

17 Hours ago
alt
alt

17 Hours ago
alt
alt

17 Hours ago

Product Specifications

Dehumidification Systems

We have successfully launched our range of Solid desiccant based dehumidification systems  both in Standard Standalone Dehumidification Series in Our Product basket as well as Customised Engineered version of Solid desiccant dehumidification systems widely known as AHU Cum Dehumidifiers and Engineered Dehumidifiers comprising of precooling coils , Post cooling coils and Various stages of filtration as desired by Process requirements. Both Standard and Customised series are available with Electrical reactivation and Steam based reactivation modes suitable to the utilities available at site.

  • Process Airflow (CMH)

    Reactivation Airflow (CMH)

    Total Electhicity (kW)

    Moisture Removal Capacity @250C, 40% RH (l/hr)

  • 2500

    800

    26.2

    15

Electrical Panel Class

IP 42

Maximum Reactivation Air

140℃

Operating Temperature

-10℃ to 50℃

Power Supply

415V, 3Phase, 50Hz

Air Filter

20 Microns on Process Inlet and Reactivation Inlet

Type of Reactivation

100% Electrical Reactivation in Standard Unit (Steam Reactivation available as an option)

  • Process Airflow (CMH)

    Reactivation Airflow (CMH)

    Total Electhicity (kW)

    Moisture Removal Capacity @250C, 40% RH (l/hr)

  • 3000

    1000

    32.2

    18

Electrical Panel Class

IP 42

Maximum Reactivation Air

140℃

Operating Temperature

-10℃ to 50℃

Power Supply

415V, 3Phase, 50Hz

Air Filter

20 Microns on Process Inlet and Reactivation Inlet

Type of Reactivation

100% Electrical Reactivation in Standard Unit (Steam Reactivation available as an option)

  • Process Airflow (CMH)

    Reactivation Airflow (CMH)

    Total Electhicity (kW)

    Moisture Removal Capacity @250C, 40% RH (l/hr)

  • 3500

    1100

    36

    21

Electrical Panel Class

IP 42

Maximum Reactivation Air

140℃

Operating Temperature

-10℃ to 50℃

Power Supply

415V, 3Phase, 50Hz

Air Filter

20 Microns on Process Inlet and Reactivation Inlet

Type of Reactivation

100% Electrical Reactivation in Standard Unit (Steam Reactivation available as an option)

  • Process Airflow (CMH)

    Reactivation Airflow (CMH)

    Total Electhicity (kW)

    Moisture Removal Capacity @250C, 40% RH (l/hr)

  • 4000

    1300

    42

    24

Electrical Panel Class

IP 42

Maximum Reactivation Air

140℃

Operating Temperature

-10℃ to 50℃

Power Supply

415V, 3Phase, 50Hz

Air Filter

20 Microns on Process Inlet and Reactivation Inlet

Type of Reactivation

100% Electrical Reactivation in Standard Unit (Steam Reactivation available as an option)

  • Process Airflow (CMH)

    Reactivation Airflow (CMH)

    Total Electhicity (kW)

    Moisture Removal Capacity @250C, 40% RH (l/hr)

  • 4500

    1500

    48

    26.5

Electrical Panel Class

IP 42

Maximum Reactivation Air

140℃

Operating Temperature

-10℃ to 50℃

Power Supply

415V, 3Phase, 50Hz

Air Filter

20 Microns on Process Inlet and Reactivation Inlet

Type of Reactivation

100% Electrical Reactivation in Standard Unit (Steam Reactivation available as an option)

  • Process Airflow (CMH)

    Reactivation Airflow (CMH)

    Total Electhicity (kW)

    Moisture Removal Capacity @250C, 40% RH (l/hr)

  • 5000

    1665

    55

    30

Electrical Panel Class

IP 42

Maximum Reactivation Air

140℃

Operating Temperature

-10℃ to 50℃

Power Supply

415V, 3Phase, 50Hz

Air Filter

20 Microns on Process Inlet and Reactivation Inlet

Type of Reactivation

100% Electrical Reactivation in Standard Unit (Steam Reactivation available as an option)

  • Process Airflow (CMH)

    Reactivation Airflow (CMH)

    Total Electhicity (kW)

    Moisture Removal Capacity @250C, 40% RH (l/hr)

  • 5500

    1830

    58

    33

Electrical Panel Class

IP 42

Maximum Reactivation Air

140℃

Operating Temperature

-10℃ to 50℃

Power Supply

415V, 3Phase, 50Hz

Air Filter

20 Microns on Process Inlet and Reactivation Inlet

Type of Reactivation